HU-430CWA Troubleshooting

Problem Possible reasons  Solutions
Power lamp is off when switched on

Humidifier is not plugged in

Power cord is damaged

Humidifier is defective or malfunctioning

Plug the humidifier into a powered electrical socket

Immediately discontinue use and contact Customer Support

Press the power button to turn it on

Power lamp is on when switched on, but no mist come out

Humidifier is not turned on

The target humidity is reached

Press the power button to turn it on

Increase the target humidity or change mode

Water shortage indicator is on

No water in the tank

Water level is low

The water level required has not yet reached the vaporization compartment

The water tank is not well positioned

The humidifier is not on a flat surface

Refill the water tank wait at least 1 minute

Wait at least 1 minute

Check the positioning of tank on the base

Check the positioning of the humidifier

Humidifier produces and unusual smell

Humidifier is new

Dirty water or water sitting too long

Residual smell from diffusing aroma oil on the aroma cotton

Take out water tank, open cover, let it stay 12 hours in cool position

Clean water tank, fill with clear water

Remove the aroma cotton, rinse it under clean water and allow it to dry

Humidifier makes a loud or unusual sound

Resonant in water tank when water is too low

Humidifier is on an unstable surface

Water tank is positioned incorrectly

Humidifier is malfunctioning

Fill water into water tank

Move the humidifier to a stable flat surface

Turn off and unplug the humidifier, then align the water tank cover with its respective opening in the inner chamber

Immediately discontinue use and contact Customer Support

The humidificaton capacity is too low

There is a natural or artificial air replacement in the room which interfere the increase of %RH

The air inlet grids, and nozzle could be blocked

Too much scale in the water basin

The humidity selected rate is too low

Water is toodirty, or water is kept too long in the tank

Check if doors and windows are closed

Check if there is no air conditioning working in the room

Remove any blocking items from the grids and the nozzle

Clean transducer

Increase mist output speed

Increase humidity setting rate

Clean water tank, change to fresh clear water

The ambient humidity is too high

Humidifier is working in CONTINUOUS MODE

The humidity target is too high

Room is not well-ventilated

Excess water tank has spilled while filling the water tank or replacing the water tank bank onto the base

Change the mode

Select a lower %RH target

Open a window to ensure proper air flow for your humidifier or move the humidifier to a more well-ventilated room

Wipe off excess water from the top and bottom of the base before replacing the water tank

There is condensation in the room

The room temperature is too low

Heat the room up

The mist suddenly stops coming out

Programmed timer period has run out

The water shortage indicator is on

The target humidity level is reached

Turn humidifier on

Refill water tank

Turn the humidifier off, orselect a higher humidity level

Incorrect humidity level is being displayed

Room is larger than the effective range of the humidifier

Moisture has built up inside of the humidity sensor

The nozzle is facing th direction of the humidity sensor

Humidity sensor is broken of defective

Move the humidifier to a room which is with suitable room size

Turn off the humidifierand allow the humidity sensor to completely air dry before resuming use

Turn the nozzle so that it is facing away from the humidity sensor

Contact Customer Support

Control panel does not work

Hands are too wet when operating contro panel

Humidifier has malfunctioned

Keep hands dry while operating the control panel

Contact Customer Support

White dust appears around the humidifier

Water being used has a high mineral content

Humidifier was not properly cleaned after last use

Use distilled water with the humidifier. If distilled water is not available, use purified or filtered water

Clean humidifier

Mist is coming out from the base

Water tank is not positioned correctly

Turn off and unplug the humidifier, then align the water tank cover with its respective opening in the inner chamber

Mist fog coming out from round nozzle

There are apertures between the nozzle and water tank

Reposition the cover and check if the nozzle is well plugged in the cover

The warm mist function does not produce warm mist

The humidifier is in warm-up phase

The mist is too fine to feel the warmth

The room temperature is too cold, and the mist may cool down too quickly

Wait a few minutes till the end of the phase

Increase the speed level

Inrease the speed level and heat the room up

Display show error code EF

Too much water in water basin

Remove water tank and empty water from the base. Check and clean particles in water outlet of watr tank that led to leakage. If no leaks, replace into base

 

The following is not considered faulty operation:
• If your water is very hard (containing abnormally high levels of minerals) the humidifier may produce white dust. This is not a malfunction. The solution would be to clean the filter more often or use softer water. 
• If you stand very close to the humidifier, you will hear the gurgling sound of water. This is normal.
• The humidifier operates very quietly but it is not completely silent. Noise levels less than 35dB(A) is considered normal.