INSTALLATION
CHOOSE YOUR LOCATION
• If tipped more than 45°, allow the unit to set upright for at least 24 hours before start up.
• Place the unit on a firm, level surface in an area with at least 50cm of free space around it to allow for proper air circulation.
• Do not operate in close proximity to walls, curtains, or other objects that may block air inlet and outlet. Keep the air inlet and outlet free of obstacles.
• Never install the unit where it could be subject to:
– Heat sources such as radiators, heat registers, stoves or other products that produce heat.
– Direct sunlight
– Mechanical vibration or shock
– Excessive dust
– Lack of ventilation, such as a cabinet or bookcase
– Uneven surface
WARNING!
• Install the unit in rooms which exceed 8 m².
• Do not install the unit in a place where inflammable gas may leak.
ATTACH THE EXHAUST HOSE
The air conditioner requires being vented outside so that the exhaust air can escape the room which coming from the appliance contains waste heat and moisture.
Do not replace or extend exhaust hose which will result in decreased efficiency,
even worse shut down the unit due to low backpressure.
Step 1: Connect the hose connector to one end of the exhaust hose.

Step 2: Connect the windows kit adapter to the other end of the exhaust hose.

Step 3: Adjust the window brackets to the width or height of your window, and insert the plastic pins to fix the desired position.
Note: do not install the window bracket to the window. This step is only to adjust to the size of your window. The bracket should be removed after the size is adjusted.

Step 4: Connect the window bracket to the window kit adapter. Ensure all connections are tight and installed properly.

Step 5: Connect the window bracket to the window.

Step 6: Adjusting the length of the flexible exhaust hose and avoid bends in the hose. Then place AC near an electrical outlet.
CONTROL PANEL AND DISPLAY

| 1 | LOCK | Press and hold this key to turn on or off the child lock function |
| 2 | MODE | Mode button Press to switch the operation mode between fan, cooling and dehumidifier |
| 3 | UP | Increasing the desired temperature (16°C - 32°C) or timer setting |
| 4 | POWER | Press to switch the machine on or off |
| 5 | DOWN | Decreasing the desired teperature or timer setting |
| 6 | SPEED | Press to switch the fan speed between HIGH and LOW |
| 7 | TIMER | Sets a timefor the unit to automatically start or stop |
| 8 | SLEEP | Press to enter sleep mode. Can only be entered in cooling mode |
| 9 | Fan speed | The display for fan speed in High or Low |
| 10 | Led display | This LED Display the Room Temperature or Time Setting |
| 11 | Mode display | The displa the Mode Setting between fan, cooling and dehumidifier |
REMOTE CONTROL

SETTINGS
START-UP AND SHUTDOWN
• Press POWER to turn the unit on.
• Press MODE button to select the desired operation mode.
• Press POWER again to turn off the power.
OPERATION MODE
The unit has four operation modes: Cool, dry, fan, sleep.
COOLING YOUR ROOM
• Select the cool mode to lower the temperature in your room.
• Press MODE button repeatedly until the COOL indicator lights up.
• Press Up/Down button to adjust the temperature which is displayed on the screen. The temperature can be set between 16°C and 32°C.
• Press SPEED button repeatedly until the desired fan speed indicator lights up.
• To control the direction of the air flow horizontally, please adjust the inner louver by hand.
Note: The air conditioner stops if the room temperature is lower than selected temperature.
VENTILATING YOUR ROOM
• Press MODE button repeatedly until the FAN indicator lights up.
• In ventilation mode the room air is circulated, but not cooled.
• Press SPEED button repeatedly to select the fan speed as desired.
DRYING YOUR ROOM
• Press MODE button on the control panel or remote control, the dry indicator lights up. The fan speed is unable to select. User should connect the hose to the drain outlet at the bottom of the unit.
Note: In this mode, the fan speed switches over to low speed and cannot be selected.
SLEEP MODE
• The sleep button can only be set in cooling mode.
• The machine enters sleep mode, all lights are dimmed at the same time, and the buzzer is disabled in sleep mode:
– 1 hour after sleep mode is turned ON, the set temperature will automatically increase by 1°C, and after another hour, the set temperature will automatically increase by 1°C.
• After sleep mode has been ON for 2 hours, the set temperature will no longer increase.
• Fan output during sleep mode: the fan automatically turns to low setting.
The wind speed output is low wind and cannot be adjusted. After exiting sleep mode, the wind speed can again be set by the user.
TIMER SETTING (1HOUR-24HOURS)
The timer has two ways of operation:
| To turn off (When power on) | -> | Press the Timer key to turn on the timer function | -> | Press Up/Down repeatedly to set the delay OFF time |
| To turn on (Whe power off) | -> | Press the Timer key to tun on the timer function | -> | Press Up/Down repeatdly to set the delay ON time |
| Cancel timer | -> | Press Up /Down repeatedly until the LED shows ‘00’. Note: by pressing POWER you will also cancel the timer |
-> |
OVERLOAD PROTECTION
In the event of a power loss, to protect the compressor there is a 3-minute delay until the compressor restarting.
DRAINAGE
SELF- EVAPORATING SYSTEM
The self-evaporating system uses the collected water to cool the condenser coils for better, more efficient performance. There is no need to empty the drainage tank in cooling mode, except in high humidity conditions. In drying mode, the drainage tank needs to be emptied. The condensed water evaporates at the condenser and disappears through the exhaust hose.
For continuous operation or unattended operating in drying mode, please connect the attached drain hose to the unit. Condensed water can automatically run into a bucket or drain.
• Switch off the unit before operating.
• Remove the plug of the water outlet opening and keep it in safe area.
• Securely and properly connect the drain hose. Make sure it is not kinked and clear of obstruction.
• Place the outlet of hose over a drain or bucket and ensure that water can freely flow out of the unit.
• Do not submerge the end of hose into water; otherwise it can cause “Air Lock” in the hose.
TO AVOID WATER SPILLAGE
• As the negative pressure of condensate drain pan is large, tilt the drain hose downward toward the floor. It is appropriate that the degree of inclination should exceed 20 degrees.
• Straighten the hose to avoid a trapping water in the hose