INSTALLATION
PRECAUTIONS
Warning:
• Observe all governing codes and ordinances.
• Do not use damaged or non-standard power cord.
• Be careful during installation and maintenance. Prohibit incorrect operation toprevent electric shock, casualty and other accidents.
SELECTION OF INSTALLATION LOCATION – BASIC REQUIREMENTS
Installing the unit in the following places may cause malfunction. If it is unavoidable, please consult the local dealer:
1. The place with strong heat sources, vapours, flammable, or explosive gas, orvolatile objects spread in the air.
2. The place with high-frequency devices (such as welding machine, medical equipment).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7. It’s not allowed to be installed on the unstable or motive base structure (suchas truck) or in the corrosive environment (such as chemical factory).
REQUIREMENT OF AIR CONDITIONER
1. Air inlet should be far away from obstacles and do not put any objects near air outlet. Otherwise, it will affect the radiation of heat discharge pipe.
2. Please try your best to keep far away from fluorescent lamp.
3. The appliance shall not be installed in the laundry. High humidity can cause malfunction.
REQUIREMENTS FOR ELECTRIC CONNECTION
Safety precautions:
1. Must follow the electric safety regulations when installing the unit.
2. According to the local safety regulations, use qualified power supply circuit.
3. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
4. Properly connect the live wire, neutral wire and grounding wire of powersocket.
5. Be sure to cut off the power supply before proceeding any work related to electricity and safety.
1. Do not put through the power before finishing installation.
2. The air conditioner is first class electric appliance. It must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance shall be installed in accordance with national wiring regulations.
PREPARATION BEFORE INSTALLATION
Note: Check if the accessories are available before installation
Accessory list

INSTALL WIRE HOOK
• Assemble the wire hook at the back of the unit with screws (the direction of wire hook is as shown in following figure)

• Wind the power cord around the wire hook

REMOVING COLLECTED WATER
When using the bottom drainage port to drain water, install the drainage pipe before use. Poor drainage will affect normal operation of the unit.
Instruction for drainage pipe installation as follows:
1. Fix the drainage pipe clip on the right of rear side plate near drainage port with a screw

2. Remove the rubber plug from the bottom drainage port

3. Put the drainage pipe into the bottom drainage port and screw it in.
4. Put the rubber plug into the other side of the drainage pipe, then fix it in thedrainage pipe clip.

DRAINAGE METHOD
1. Drainwater from the bottom drainage port
– Turn the unit off, and pull the plug from the socket.
– Place a water container under the bottom drainage port, or move the unit to a place where it can drain.
– Remove the rubber plug of the bottom drainage port to drain water.
– After draining, insert the rubber plug.
– Insert the plug into the socket and turn the unit on.

2. Drain water from the middle drainage port.
Note: Water can be automatically emptied into a floor drain by attaching 13 mm inner diameter hose (not included)
– Remove the drain cap by turning it anti clockwise then remove the rubber stopper from the spout.

– Screw the drain connector to the spout by turning clockwise.

– Insert the drainage hose into the drain connector

Note: When using continuous drainage option from the middle drainage port, place portable on a level surface and make sure garden hose is clear of any obstructions and is directed downward. Placing portable on an uneven surface or improper hose installation may result in water filling up the chassis and causing the unit to shut off. Empty water in the chassis if shut off occurs, then check portable location and hose for proper setup.

INSTALLATION OF HEAT DISCHARGE PIPE
1. Rotate joint A and Rear clip clockwise into the two ends of heat discharge pipe.

2. Insert joint A of heat discharge pipe (The side with TOP is upwards) into the groove until you hear a sound.

3. Lead the heat discharge pipe outdoors. For best effect, choose a window without direct sunlight. Keep the other windows closed.

4. Slide and open the exhaust cover on the window panel and attach the Rear clip. (Optional)

NOTE OF INSTALLING HEAT DISCHARGE PIPE
• In order to improve cooling efficiency, the heat discharge pipe should be as short as possible and flat without curve to ensure smooth heat discharge.
• The length of the heat discharge pipe is less than 1m. It is recommended to use it with shortest length.
• When installing, heat discharge pipe should be as flat as possible. Don’t prolong the pipe or connect it with other heat discharge pipe.