WDH-20 Malfunction codes

No. Malfunction name Display code Unit`s condition Possible causes
1 Ambient 
Temperature 
Sensor 
Malfunction
F1 Compressor and fan 
motor stop.
This button is invalid
  • Ambient temperature sensor is loosen or is poorly connected with the terminal of display board.
  • Some element of display board may have been put upside down and cause short circuit.
  • Ambient temperature sensor is damaged
  • Display board is damaged.
2 Tube
Temperature
Sensor
Malfunction
F2 Compressor and fan 
motor stop.
This button is invalid
  • Temperature sensor on the evaporator is loosen or is poorly connected with the terminal of display board
  • Some element of display board may have been put upside down and cause short circuit.
  • Temperature sensor on the evaporator is damaged
  • Display board is damaged.
3 Humidity 
Sensor 
Malfunction
L1 Compressor and fan 
motor stop.
This button is invalid
  • Humidity sensor is short-circuited
  • Humidity sensor is damaged
  • Display board is damaged.
4 Freon-lacking 
protection
F0 The compressor stops; 
the fan motor keeps 
on running.
  • Refrigerant is leaking.
  • System is blocked
5 High-temperature 
over load 
protection
H3 The compressor stops; 
the fan motor keeps 
on running.
  • Ambient operation condition is bad.
  • The evaporator and condenser are blocked with filth.
  • The system is abnormal.